NDIR Carbon Dioxide Gas Sensor, Maintenance-free
Model no.CS200
Key Specifications / Features
NDIR Carbon Dioxide Gas Sensor Provider: CO2 Gas Sensors, Non-dispersive Infrared (NDIR), Maintenance Free, Automatic Calibration, 400-5000ppm Range.Detail Information
Features
·Non-dispersive infrared (NDIR) principle
·Easy to install
·Long service life (after strict reliability test)
·Automatic calibration
·Maintenance free
·High sensitivity to CO2
·Low power consumption
·High measurement range (Products with more than 10000ppm range can be customized.)
·Full range temperature compensation
·NDIR dual-channel technology
Application Environments
·Fresh Air System
·Central Air Conditioning
·Breeding and Planting
·Industrial Monitoring
·Environmental Protection
Specification Parameters
Measurement Range: 400-5000ppm
Measurement Precision: ±(50ppm + 5% reading)
Power-on Settling Time: 30s
Data Refresh Rate: 2s
Zero Setting Cycle: The sensor is automatically calibrated every 15 consecutive power-on days (optional). (Automatic calibration is not enabled by default in 15 days.)
Working Condition: -10-50℃; 0-95% RH (non-condensing)
Storage Condition: -30-70℃; 0-95% RH (non-condensing)
Working Voltage: DC (5.0±0.1) V, Ripple<50mV
Mean Operating Current: <40mA
Communication Interface: UART TTL (3.3V)
Size: 33 x 21 x 17.2 mm
Product Life: ≥10 years
Product Classification
·Non-dispersive infrared (NDIR) principle
·Easy to install
·Long service life (after strict reliability test)
·Automatic calibration
·Maintenance free
·High sensitivity to CO2
·Low power consumption
·High measurement range (Products with more than 10000ppm range can be customized.)
·Full range temperature compensation
·NDIR dual-channel technology
Application Environments
·Fresh Air System
·Central Air Conditioning
·Breeding and Planting
·Industrial Monitoring
·Environmental Protection
Specification Parameters
Measurement Range: 400-5000ppm
Measurement Precision: ±(50ppm + 5% reading)
Power-on Settling Time: 30s
Data Refresh Rate: 2s
Zero Setting Cycle: The sensor is automatically calibrated every 15 consecutive power-on days (optional). (Automatic calibration is not enabled by default in 15 days.)
Working Condition: -10-50℃; 0-95% RH (non-condensing)
Storage Condition: -30-70℃; 0-95% RH (non-condensing)
Working Voltage: DC (5.0±0.1) V, Ripple<50mV
Mean Operating Current: <40mA
Communication Interface: UART TTL (3.3V)
Size: 33 x 21 x 17.2 mm
Product Life: ≥10 years
Product Classification
PN | Range (ppm) | Product Type | Packing Specification | L*W*H (mm) |
CS200 | 400-5000 | CO2 | 90 pcs/layer, 7 layers/ctn | 510*295*295 |