High Eft Indoor PM10 Laser Dust Sensor

High Eft Indoor PM10 Laser Dust Sensor

Key Specifications / Features

High Eft Indoor PM10 Laser Dust Sensor Provider: High Eft High Precision Indoor PM10 Laser Dust Sensors, for Environmental Monitoring, UART TTL, UART TTL.

Detail Information

High Eft Indoor Pm10 Laser Dust Sensor

Model Number: PS5308-M_B
Type: Air quality sensor
Brand Name: Pulse sensor
Usage: Intelligence appliance, air quality monitoring, Environmental Monitoring
Theory: Principle of laser scattering detection
Output: UART TTL, UART TTL
Measuring range: 0-1000 ug/m3
Power supply: DC 5±0.5V
Features: High Precision
Certificate: ROHS, REACH, ISO9001
Response time: <5s
Accuracy: ≥100 ug/ m3:±10% <100 ug/ m3:±10 ug/ m3
Temperature range: -30℃ - 70℃
Size: 48mm*40mm*13.5mm
Packaging & Delivery: 70 PCS/layer, 6 layers per box, 420 PCS in total
 
Parameter Index
type PM2.5
range 0-1000 ug/ m³
Consistency ≥100 ug/ m³:±10%;<100 ug/ m³: ±10 ug/ m³
Accuracy ≥100 ug/ m³:±10%;<100 ug/ m³: ±10 ug/ m³
data interface UART TTL, 9600 bps
power supply DC 5±0.5V, ripple<50mv
working environment Temperature: -15℃ - 60℃ ;Humidity: 0 - 90% RH(no condensation)
Storage Conditions Temperature: -30℃ - 70℃ ;Humidity: 0 - 90% RH(no condensation)
weight 26g
size 48mm*37mm*12mm
MTTF ≥30000H

PS5308-M/B laser dust sensor
  • Real-time detection output
  • Accurate and reliable data
  • Minimum resolution particle size 0.3um
  • Synchronous detection of PM1.0, PM2.5, PM10, BSP
  • Specific laser anti-attenuation constant brightness function
  • Anti-interference capability
  • Standard TTL Serial port data output
  • Small size for easy installation
Application Environment
  • Air purifier
  • Fresh air system
  • Air conditioner
  • Car Air Purifier
  • Air quality detector
  • Environmental Monitoring
  • Hand-held air quality detector
Technical measurement index
 
Parameter Range Accuracy
PM1.0 0-1000 ug/m³ ±10% or ±10 ug/m³
PM2.5 0-1000 ug/m³ ±10% or ±10 ug/m³
PM10 0-1000 ug/m³ ±25% or ±25 ug/m³
BSP(Large particulate concentration levels)* 0-100 Lev ±25% or ±5Lev
*: The concentration level ranges from 0 to 100. Particle mass concentration PM < 6ug/m³ corresponds to class 0, 6 ≤ PM < 12ug/m³ corresponds to class 1, and so on, 600ug/m³ and above corresponds to class 100.

Specification Parameter
 
Parameter Index
Data Interface UART TTL, 9600 bps
Power supply DC 5±0.5V, Ripple<50mV
Working Condition Temp: -15℃ - 60℃
Humidity: 0 - 90% RH
Storage Condition Temp: -30℃ - 70℃
Humidity: 0 - 90% RH
Weight 26g
Size 48mm*37mm*12mm
MTTF ≥30000H

Product classification
 
PN Range (ug/m³) Product Type Packing specification L*W*H (MM)
PS5308-M/B 0-1000 PM2.5, PM10 70pcs/layer, 6 layers/ctn 510*295*295

Tags: